求翻译:It is interesting to note, for instance, that the transmission line currents in the simulation case described above are not symmetrical in steady-state. To accentuate the unbalance, the load at the receiving end may be removed. It can then be observed that the ‘B’ Phase current is approximately 10% higher than the ‘A’ 是什么意思?

待解决 悬赏分:1 - 离问题结束还有
It is interesting to note, for instance, that the transmission line currents in the simulation case described above are not symmetrical in steady-state. To accentuate the unbalance, the load at the receiving end may be removed. It can then be observed that the ‘B’ Phase current is approximately 10% higher than the ‘A’
问题补充:

  • 匿名
2013-05-23 12:21:38
有趣的是,要注意的,例如,上文所述的在模拟的情况下传输线电流在稳态对称。突出的不平衡,在接收端的负荷,可能会被删除。然后,可以观察到,“B”相电流的'A'和'C'相电流比高出约10%。长的输电线路经常换位,以平衡线电流。有两种方式纳入RTDS仿真案transpostion。首先,transpostion可仿照明确分成三段长度相等的输电线路。在第1和第之间的连接2是单相旋转。移动A相导线1导体2导体2,B相导线3和C相导线3导体1。另一个轮换是在第2和3之间的连接点。有了这样的换位计划,每个阶段将占据1导体,导体2和指挥3的长度相同。这种方法要求用户分配3传输线模型和6个额外的节点。
  • 匿名
2013-05-23 12:23:18
值得注意的是,例如,在模拟传输线电流上述案件不对称的稳定状